Seawall repair in West Palm Beach can turn into a bulkhead replacement, and Section 94-378 of the city code says a replacement has to include sloping rip-rap or permeable material with plants.

Get a free match

This site is a free referral service. We are not a contractor. We connect you with licensed, insured marine contractors.

Call or text (561) 785-1204

Call now or send a text with your address and what you need.

Replacing a bulkhead? Read b.4 first

The section is short, so here it is whole.

West Palm Beach code: shoreline management

a. Docks, marinas, etc.

1. New boat basins, marinas, docks and other mooring facilities are prohibited unless approved by the appropriate governmental agencies, such as the U.S. Army Corp of Engineers, state department of environmental regulation, state department of natural resources, board of trustees of the internal improvement trust fund, and the South Florida Water Management District.

2. In no event shall any new boat basin, marina, dock, or any other structure be approved which would constrict water circulation in Lake Worth.

b. Shoreline stabilization.

1. Within a proposed development in the coastal area, there shall be no net loss of any marine or terrestrial habitat, or native shoreline vegetation that are identified in the existing natural resources section of the conservation element of the comprehensive plan and displayed on the vegetative cover and wildlife habitats map at Figure 11-3 of that element.

2. Within a proposed development, natural shoreline lacking wetland vegetation shall be planted with wetlands vegetation in order to minimize potential flood damage, stabilize the shoreline, and trap sediments and other nonpoint source pollutants.

3. Shoreline hardening structures may be used only if erosion is a threat to life and property and the use of vegetation has failed to stabilize the shoreline.

4. New shoreline hardening structures or replacement of any existing bulkheads shall consist of or include sloping structures of rip-rap or permeable materials combined with vegetation.

(Code 1979, § 33-147)

City of West Palm Beach Code of Ordinances, Sec. 94-378, Shoreline management (whole section). Official source, checked November 21, 2026.

Can a repair skip the state permit?

Paragraph (e) is about putting a wall back where it stood. The long opening paragraph keeps city and county rules in play.

Florida Statutes: seawall exemptions

(1) A permit is not required under this chapter, chapter 373, chapter 61-691, Laws of Florida, or chapter 25214 or chapter 25270, 1949, Laws of Florida, and a local government may not require a person claiming this exception to provide further department verification, for activities associated with the following types of projects; however, except as otherwise provided in this subsection, this subsection does not relieve an applicant from any requirement to obtain permission to use or occupy lands owned by the Board of Trustees of the Internal Improvement Trust Fund or a water management district in its governmental or proprietary capacity or from complying with applicable local pollution control programs authorized under this chapter or other requirements of county and municipal governments:

[...]

(e) The restoration of seawalls at their previous locations or upland of, or within 18 inches waterward of, their previous locations. This may not affect the permitting requirements of chapter 161, and department rules shall clearly indicate that this exception does not constitute an exception from the permitting requirements of chapter 161.

[...]

(i) The construction of private docks of 1,000 square feet or less of over-water surface area and seawalls in artificially created waterways when such construction will not violate existing water quality standards, impede navigation, or affect flood control. This exemption does not apply to the construction of vertical seawalls in estuaries or lagoons unless the proposed construction is within an existing manmade canal where the shoreline is currently occupied in whole or part by vertical seawalls.

[...]

(o) The construction of private seawalls in wetlands or other surface waters when such construction is between and adjoins at both ends existing seawalls; follows a continuous and uniform seawall construction line with the existing seawalls; is not more than 150 feet in length; and does not violate existing water quality standards, impede navigation, or affect flood control. However, in estuaries and lagoons the construction of vertical seawalls is limited to the circumstances and purposes stated in s. 373.414(5)(b)1.-4. This paragraph does not affect the permitting requirements of chapter 161, and department rules must clearly indicate that this exception does not constitute an exception from the permitting requirements of chapter 161.

Florida Statutes, s. 403.813(1), opening paragraph and paragraphs (e), (i) and (o). [...] marks paragraphs left out. Official source and a second official copy, checked November 21, 2026.

How far back from the water?

On a tidal lot, a seawall cuts the setback from 25 feet to 15.

West Palm Beach code: waterfront setbacks

c. Additional setback requirements.

1. Multifrontage lots. Unless otherwise provided by this chapter, the required front setback shall be required for all lots having frontage on more than one street.

2. Waterfront tidal setback. All residential principal and accessory structures on waterfront lots subject to tidal action shall be set back at least 25 feet from the mean highwater mark. Where seawalls constructed on or behind the mean highwater mark exist, the setback shall be at least 15 feet.

3. Fresh water setback. All residential principal and accessory uses located on nontidal waterfront lots shall be set back at least ten feet from the mean highwater mark. The mean highwater mark shall be determined by the overflow elevation of any controlling device, structure, pipe, or ditch.

(Code 1979, § 33-112; Ord. No. 3744-04, § 4, 9-27-2004; Ord. No. 4370-11, § 3, 10-3-2011; Ord. No. 4449-13, § 24, 3-19-2013; Ord. No. 4660-16, § 9, 12-5-2016)

City of West Palm Beach Code of Ordinances, Sec. 94-305, Setbacks, subsection (c). Official source, checked November 21, 2026.

Is there a minimum seawall height in West Palm Beach?

We searched the city code and didn't find one. So the cap elevation comes from the engineer's design. Ask what number they're using, and how it lines up with the walls on either side of you.