West Palm Beach Seawall Permit Rules
West Palm Beach seawall permit work brings in the dock rules too when there's a dock on the wall, because the city measures docks from the bulkhead. Below is the city's own text.
Get a free match Call (561) 785-1204
Papers that go in with a dock application
Item b asks for plans sealed by a Florida engineer, architect or landscape architect.
2. Additional application requirements. Upon submittal of an application for a building permit, two copies of each of the following documents shall be provided with the application. In addition, docks necessitating a Class A special use permit shall provide such additional documents or materials in such quantities required by the city's development application.
a. Proof that the applicant is the owner of the property and the holder of the riparian rights;
b. Construction plans prepared by and under the seal of a Florida registered professional engineer, architect or landscape architect;
c. A site plan drawn to scale sufficient to represent all elements of the proposed dock and of the riparian property from which the dock will project, and of the adjacent properties on both sides thereof;
d. A cross section showing all elements of the proposed dock, the bottom of the waterway, as well as the mean high waterline and mean low waterline.
e. Valid written approval of the proposed dock by the Florida Department of Environmental Protection (DEP), the U.S. Army Corps of Engineers (the Corps) and/or the South Florida Water Management District (SFWMD) is required unless prohibited by general law. Such written approvals shall contain the date on which the proposed dock was approved.
City of West Palm Beach Code of Ordinances, Sec. 94-313, Docks, item 2 (additional application requirements). Official source, checked November 21, 2026.
Length and height are tied to the wall
If a new wall goes in at a different spot or a higher cap, ask the contractor what that does to the dock.
i. Length. Dock length shall be measured from the mean high waterline, or the bulkhead, to the furthermost point of the dock, finger pier, or terminal platform (excluding dolphins, pilings, and other mooring related facilities).
i. Maximum dock length shall not exceed the minimum dock length approved by the Department of Environmental Protection (DEP), the Army Corps of Engineers (the Corps) and/or the South Florida Water Management District (SFWMD), based on the minimum water depth necessary to moor the vessels at low tide and minimum length to clear existing sea grass beds, up to a maximum of 100 feet.
ii. Docks located along the northern bank of the West Palm Beach Canal, east of Dixie Highway, shall not exceed 40 feet in length.
iii. The city commission may, by approval of a Class A special use permit, authorize a length greater than that permitted by subsections (i.) and (ii). above to reasonably accommodate the allowed number of boat slips, avoid damage to the marine environment, avoid extensive dredging of the lake bottom, or permit full use and enjoyment of the dock.
k. Height. With the exception of security fences, boat lifts, and mooring devices, no buildings or structures shall be constructed on the proposed dock and no portion of a dock shall extend above the top surface of the bulkhead to which it is affixed, if any. Dolphins may extend to a reasonable height to provide safe mooring of a boat.
City of West Palm Beach Code of Ordinances, Sec. 94-313, Docks, item 3, paragraphs i (Length) and k (Height). Official source, checked November 21, 2026.
Steps over the seawall
Some lots hold riparian rights that aren't next to the house (the code calls them noncontiguous). They get their own rule on steps.
b. Steps. As necessary, steps may be constructed on the upland side of the seawall in order to provide access over the seawall to the dock. Such steps shall:
i. Be constructed in accordance with the minimum requirements of the Florida Building Code; and
ii. Shall be constructed of concrete or stone; and
iii. Shall not contain a handrail unless otherwise required by the Florida Building Code.
City of West Palm Beach Code of Ordinances, Sec. 94-313, Docks, item 4, paragraph b (Steps). Official source, checked November 21, 2026.
Seawalls in a V zone
Is your lot mapped Zone V on the FEMA flood map? Then the city's flood rules add this test.
g. Other development in coastal high hazard areas (Zone V). In coastal high hazard areas, development activities other than buildings and structures shall be permitted only if also authorized by the appropriate federal, state or local authority; if located outside the footprint of, and not structurally attached to, buildings and structures; and if analyses prepared by qualified registered design professionals demonstrate no harmful diversion of floodwaters or wave run-up and wave reflection that would increase damage to adjacent buildings and structures. Such other development activities include but are not limited to:
1. Bulkheads, seawalls, retaining walls, revetments, and similar erosion control structures;
2. Solid fences and privacy walls, and fences prone to trapping debris, unless designed and constructed to fail under flood conditions less than the design flood or otherwise function to avoid obstruction of floodwaters; and
3. On-site sewage treatment and disposal systems defined in 64E-6.002, F.A.C., as filled systems or mound systems.
(Ord. No. 4729-17, § 3, 9-14-2017; Ord. No. 5116-24, § 12, 11-24-2024)
City of West Palm Beach Code of Ordinances, Sec. 18-296, Other development, subsection (g). Official source, checked November 21, 2026.